Cisco Call Manager - CUCM ungraceful shutdown error messages occur when Cisco CUCM servers are powered off without being shut down. | GOLINE
Goline Logo

FAQ

News

  • In the supply and logistics sectors, email communication is pivotal. However, organizations face threats like email fraud and phishing. GOLINE SA's clients struggled with configuring email authentication protocols manually. To address this challenge, GOLINE SA became an MSP Partner of PowerDMARC, collaborating to streamline implementation and management. PowerDMARC's cloud-based platform automated DMARC, SPF, and DKIM protocols for GOLINE SA's clients. This streamlined the transition to DMARC enforcement policies, bolstering domain protection without compromising email deliverability. The intuitive platform facilitated easy navigation and provided detailed reporting for proactive issue resolution. GOLINE SA's clients experienced tangible benefits: Enhanced Email Security: Automated protocols...
  • Route RPKI validation April 1st, 2022
    RPKI is a security framework by which network owners can validate and secure the critical route updates or Border Gateway Protocol (BGP) announcements between public Internet networks. BGP is essentially the central nervous system of the Internet and one of its fundamental building blocks. The main function of BGP is to facilitate efficient routing between Autonomous Systems (AS), by building and maintaining the Internet routing table. The Internet routing table is effectively the navigation system of the Internet and without it, traffic would be unable to flow between its constituent networks. Unfortunately, routing equipment alone cannot distinguish between legitimate and malicious routing announcements,...
  • RIPE – Atlas Anchor February 17th, 2022
    We have become an even more integral part of the RIPE Atlas project by hosting an anchor, a device that allows for latency analysis of traffic between autonomous systems.https://atlas.ripe.net/probes/7073/RIPE Atlas anchors play an integral role in the RIPE Atlas network by acting both as enhanced RIPE Atlas probes with more measurement capacity, as well as regional measurement targets within the greater RIPE Atlas network. Anchors are able to perform many more measurements than a regular RIPE Atlas probe, and the large amount of data they collect is made available to everyone. In addition, anchors act as powerful targets that can...

Cisco Call Manager – CUCM ungraceful shutdown error messages occur when Cisco CUCM servers are powered off without being shut down.

Caparrelli Paolo Cisco 12 January 2023

CUCM ungraceful shutdown error messages occur when Cisco CUCM servers are powered off without being shut down.

In the latest updates to CUCM 12.5 and CUCM 14, Cisco has added unclean CUCM shutdown detection to CVOS/UC OS.

If a server is powered off without being shut down, the following warning message will be displayed after the server is booted again:

Cisco CUCM ungraceful shutdown detected

If you don’t address the issue, you will receive, at most, limited support from TAC to assist with the CUCM ungraceful shutdown before you are obliged to rebuild.

This change comes from improvement CSCva87117. It makes sense from Cisco’s perspective to implement this because filesystem corruption can have severe impacts on systems and can be difficult to identify. We assume that this feature will be coming to other updated versions of the major UC appliances if it isn’t already present.

We’ve seen issues in client environments at sites with unreliable power infrastructure. Although UPSs are in place, they have limited run time that cannot handle the length of some power outages. Having to rebuild a server twice in the same month made us take a closer look at how this issue could be avoided.

All ungraceful shutdowns and restarts will not cause corruption.

Steps that can be done to check integrity:

Database: cli command ‘show tech dbintegrity’ – will check database integrity. OS:

Booting off the recovery.iso and running file system check – will check OS file system integrity.

1) There is a COP file on cisco.com that will add CLI command that will let you remove the warning message: ciscocm.add_utils_ungraceful_warn_disable_v1.0.k4.cop.sha512

CLI Command: utils ungraceful warn disable

After this change, the ungraceful shutdown will still be documented in the system-history.log

Note: Versions 12.5.1SU6 and 14SU2 and higher have this CLI command by default.